Mishkat

NPS 2 ° NPS 3½

2-3½ Other Dimensions:
1/8-1½ | 4-6 | 8-12|14-18 | 20-26
NPS
Specified
Outside
Diameter
in
(mm)
Specified
Wall
Thickness
in
(mm)
Nominal Weight
(Mass)
per Unit Length
Plain End
lb/ft
(kg/m)
2
2.375
(60.3)
0.154
(3.91)
3.66
(5.44)
0.218
(5.54)
5.03
(7.48)
0.344
(8.74)
7.47
(11.11)
0.436
(11.07)
9.04
(13.44)
2.875
(73.0)
0.203
(5.16)
5.80
(8.63)
0.276
(7.01)
7.67
(11.41)
0.375
(9.52)
10.02
(14.90)
0.552
(14.02)
13.71
(20.39)
3
3.500
(88.9)
0.125
(3.18)
4.51
(6.72)
0.156
(3.96)
5.58
(8.29)
0.188
(4.78)
6.66
(9.92)
0.216
(5.49)
7.58
(11.29)
0.250
(6.35)
8.69
(12.93)
0.281
(7.14)
9.67
(14.40)
0.300
(7.62)
10.26
(15.27)
0.438
(11.13)
14.34
(21.35)
0.600
(15.24)
18.60
(27.68)
4.000
(101.6)
0.125
(3.18)
5.18
(7.72)
0.156
(3.96)
6.41
(9.53)
0.188
(4.78)
7.66
(11.41
0.226
(5.74)
9.12
(13.57)
0.250
(6.35)
10.02
(14.92)
0.281
(7.14)
11.17
(16.63)
0.318
(8.08)
12.52
(18.63)
NPS
Specified
Outside
Diameterb
in
(mm)
Specified
Wall
Thickness
in
(mm)
Nominal Weight
(Mass)
per Unit Length
Plain End
lb/ft
(kg/m)
NPS Weight
Class
Schedule
No.
Test Pressure
Apsi
(kPa)
Grade A
Grade B
2
STD
40
2300
(15900)
2500
(17200)
XS
80
2500
(17200)
2500
(17200)
160
2500
(17200)
2500
(17200)
XXS
2500
(17200)
2500
(17200)
STD
40
2500
(17200)
2500
(17200)
XS
80
2500
(17200)
2500
(17200)
160
2500
(17200)
2500
(17200)
XXS
160
2500
(17200)
2500
(17200)
3
1290
(8900)
1500
(1000)
1600
(11000)
1870
(12900)
1930
(13330)
2260
(15600)
STD
40
2220
(15300)
2500
(17200)
2500
(17200)
2500
(17200)
2500
(17200)
2500
(17200)
XS
80
2500
(17200)
2500
(17200)
160
2500
(17200)
2500
(17200)
XXS
2500
(17200)
2500
(17200)
1120
(7700)
1310
(19000)
1400
(6700)
1640
(11300)
1690
(11700)
1970
(13600)
STD
40
2030
(14000)
2370
(16300)
2250
(15500)
2500
(17200)
2500
(17200)
2500
(17200)
XS
80
2800
(19300)
2800
(19300)
Grade A
Grade B
NPS
Weight
Class
Schedule
No.
Test Pressure
Apsi
(kPa)
2-3½
Other Dimensions:
1/8-1½ | 4-6 | 8-12|14-18 | 20-26

Notes:

1. For specified wall thicknesses greater than the heaviest specified wall thickness listed in this table for the applicable specified outside diameter, the test pressure shall be the highest value listed for the applicable specified outside diameter and grade.

2. For pipe smaller than NPS 2 with a specified wall thickness less than the lightest specified wall thickness listed in this table for the applicable specified outside diameter and grade.

3. For all sizes of Grade A and B pipe smaller than NPS 2, the test pressures were assigned arbitrarily. Test pressures for intermediate specified outside diameters need not exceed those given in this table for the next larger listed size.